:MASK:OUTPut
Syntax
:MASK:OUTPut <bool>
:MASK:OUTPut?
:MASK:OUTPut?
Description
Enable or disable the sound prompt when the failed waveforms are detected, or query the
status of the sound prompt.
Parameter
Name
Type
Range
Default
<bool>
Bool
{{0|OFF}|{1|ON}}
0|OFF
Explanation
OFF: failed waveforms are detected, there are display and output but the beeper
does not sound..
ON: failed waveforms are detected, there are display and output and the beeper
sounds (not related to the on/off state of the sound).
Return
Format
The query returns 0 or 1.
Example
:MASK:OUTPut ON
:MASK:X
Syntax
:MASK:X <x>
:MASK:X?
:MASK:X?
Description
Set or query the horizontal adjustment parameter in the pass/fail test mask.
Parameter
Name
Type
Range
Default
<x>
Real
0.02 to 4
0.24
Explanation
In the range, the step is 0.02.
Return
Format
The query returns the horizontal adjustment parameter in scientific notation.
Example
:MASK:X 0.28 /*Set the horizontal adjustment parameter to 0.28div*/
:MASK:X? /*The query returns 2.800000e-01*/
:MASK:Y
Syntax
:MASK:Y <y>
:MASK:Y?
:MASK:Y?
Description
Set or query the vertical adjustment parameter in the pass/fail test mask.
Parameter
Name
Type
Range
Default
<y>
Real
0.04 to 5.12
0.48
Explanation
In the range, the step is 0.04.
Return
Format
The query returns the vertical adjustment parameter in scientific notation.
Example
:MASK:Y 0.36 /* Set the vertical adjustment parameter to 0.36div*/
:MASK:Y? /*The query returns 3.600000e-01*/