Техническая Спецификация для Emmerich Li-ion battery ICR-18650 NQ-SP 3.7 V 2600 mAh (Ø x H) 18.4 mm x 70 mm 233974

Модели
233974
Скачать
Страница из 16
-SAMSUNG SDI Confidential Proprietary – 
 
Spec. No. 
ICR18650-26F 
Version No. 
0.0 
 
 
 
 
 
4. Outline Dimensions 
        See the attachment (Fig. 1)   
5. Appearance 
        There shall be no such defects as scratch, rust, discoloration, leakage which 
        may adversely affect commercial value of the cell.
 
 
6. Standard Test Conditions 
   
    6.1 Environmental Conditions 
            Unless otherwise specified, all tests stated in this specification are   
            conducted at temperature 25
±5℃  and humidity 65±20%. 
 
    6.2 Measuring Equipment 
            (1) Ammeter and Voltmeter 
                    The ammeter and voltmeter should have an accuracy of   
                    the grade 0.5 or higher. 
            (2) Slide caliper 
                    The slide caliper should have 0.01 mm scale. 
            (3) Impedance meter 
                    The impedance meter with AC 1kHz should be used. 
 
7. Characteristics 
   
7.1 Standard Charge 
        This "Standard Charge" means charging the cell with charge current   
            1300mA and constant voltage 4.2V at 25
℃  for 3hours.   
 
7.2 Standard Discharge Capacity 
        The standard discharge capacity is the initial discharge capacity of the cell, which is   
measured with discharge current of 520mA with 2.75V cut-off at 25
℃  within 1hour   
after the standard charge. 
                          Standard Discharge Capacity       
≥   2550mAh 
 
7.3 Initial internal impedance 
Initial internal impedance measured at AC 1kHz after rated charge. 
                            Initial internal impedance       
≤   100mΩ  
7.4 Temperature Dependence of Discharge Capacity 
            Capacity comparison at each temperature, measured with discharge   
constant current 520mA and 2.75V cut-off after the standard charge is   
as follows.             
 
              Note: If charge temperature and discharge temperature is not the same,   
Charge Temperature 
Discharge temperature 
25
℃ 
-10
℃ 
0
℃ 
25
℃ 
40
℃ 
Relative Capacity 
50% 
80% 
100% 
80%