Техническая Спецификация для Honeywell CSLA1CH Linear (direct Tab Visual) Current Sensor 8 - 16 Vdc CSLA1CH

Модели
CSLA1CH
Скачать
Страница из 4
Solid State Sensors
CS Series
Linear Current Sensors
58
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
FEATURES
1 Linear output
1 AC or DC current sensing
1 Through-hole design
1 Fast response time
1 Output voltage isolation from input
1 Minimum energy dissipation
1 Maximum current limited only by
conductor size
1 Adjustable performance and built-in
temperature compensation assures
reliable operation
1 Accurate, low cost sensing
1 Operating temperature range –25 to
85
°
C
1 Housing: PET polyester
LINEAR CURRENT SENSORS
MICRO SWITCH CS series linear current
sensors incorporate our 91SS12-2 and
SS94A1linear output Hall effect transduc-
er (LOHET
TM
). The sensing element is as-
sembled in a printed circuit board mount-
able housing. This housing is available in
four configuration as shown in mounting
dimension figures 1, 1a, 2 and 2a. Normal
mounting is with 0.375 inch long 4-40
screw and square nut (not provided) in-
serted in the housing or a 6-20 self-tap-
ping screw. The combination of the sen-
sor, flux collector, and housing compris-
es the holder assembly. These sensors
are ratiometric.
ORDER GUIDE — BOTTOM MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensed
Sensitivity
Mtg.
Supply
Supply
Current
Offset
mV&N*
Offset
Response
Catalog
Dim.
Volt.
Current
(Amps
Volt.
At 12 VDC
Shift
Time
Listing
Fig.
(Volts DC) (mA Max.) Peak)
(Volts±10%)
Nominal
± TOL
(%/
°
C)
(
µ
Sec.)
CSLA1CD
1
8 to 16
19
57
Vcc/2
49.6
5.8
±.05
3
CSLA1CE
1
8 to 16
19
75
Vcc/2
39.4
4.4
±.05
3
CSLA1DE
2
8 to 16
19
75
Vcc/2
39.1
4.8
±.05
3
CSLA1CF
1
8 to 16
19
100
Vcc/2
29.7
2.7
±.05
3
CSLA1DG
2
8 to 16
19
120
Vcc/2
24.6
2.1
±.05
3
CSLA1CH
1
8 to 16
19
150
Vcc/2
19.6
1.8
±.05
3
CSLA1DJ
2
8 to 16
19
225
Vcc/2
13.2
1.2
±.05
3
CSLA1EJ
1a
8 to 16
19
225
Vcc/2
13.2
1.5
±.05
3
CSLA1DK
2
8 to 16
19
325
Vcc/2
9.1
1.7
±.05
3
CSLA1EK
1a
8 to 16
19
325
Vcc/2
9.4
1.3
±.05
3
CSLA1EL
1a
8 to 16
19
625
Vcc/2
5.6
1.3
±.05
3
BOTTOM MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Sensed
Sensitivity
Mtg.
Supply
Supply
Current
Offset
mV&N*
Offset
Response
Catalog
Dim.
Volt.
Current
(Amps
Volt.
At 8 VDC
Shift
Time
Listing
Fig.
(Volts DC) (mA Max.) Peak)
(Volts±2%)
Nominal
± TOL
(%/
°
C)
(
µ
Sec.)
CSLA2CD
1
6 to 12
20
72
Vcc/2
32.7
3.0
±.02
3
CSLA2CE
1
6 to 12
20
92
Vcc/2
26.1
2.1
±.02
3
CSLA2DE
2
6 to 12
20
92
Vcc/2
25.6
2.2
±.02
3
CSLA2CF
1
6 to 12
20
125
Vcc/2
19.6
1.3
±.02
3
CSLA2DG
2
6 to 12
20
150
Vcc/2
16.2
1.1
±.02
3
CSLA2DJ
2
6 to 12
20
225
Vcc/2
8.7
0.6
±.020
3
CSLA2DH
2
6 to 12
20
235
Vcc/2
9.8
1.1
±.0125
3
CSLA2EJ
1a
6 to 12
20
310
Vcc/2
7.6
0.7
±.0125
3
CSLA2DK
2
6 to 12
20
400
Vcc/2
5.8
0.5
±.0125
3
CSLA2EL
1a
6 to 12
20
550
Vcc/2
4.3
0.4
±.0125
3
CSLA2EM
1a
6 to 12
20
765
Vcc/2
3.1
0.3
±.007
3
CSLA2EN
1a
6 to 12
20
950
Vcc/2
2.3
0.2
±.007
3
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
* N = number of turns
PDFINFO
p a g e - 0 5 8