Техническая Спецификация для Honeywell CSLA1CH Linear (direct Tab Visual) Current Sensor 8 - 16 Vdc CSLA1CH

Модели
CSLA1CH
Скачать
Страница из 4
Solid State Sensors
CS Series
Linear Current Sensors
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada
59
SIDE MOUNT WITH 9SS SENSOR, SOURCE OUTPUT
Sensed
Sensitivity
Mtg.
Supply
Supply
Current
Offset
mV&N*
Offset
Response
Catalog
Dim.
Volt.
Current
(Amps
Volt.
At 12 VDC
Shift
Time
Listing
Fig.
(Volts DC) (mA Max.) Peak)
(Volts±10%)
Nominal
± TOL
(%/
°
C)
(
µ
Sec.)
CSLA1GD
2a
8 to 16
19
57
Vcc/2
49.6
5.8
±.05
3
CSLA1GE
2a
8 to 16
19
75
Vcc/2
39.4
4.4
±.05
3
CSLA1GF
2a
8 to 16
19
100
Vcc/2
29.7
2.7
±.05
3
SIDE MOUNT WITH SS9 SENSOR, SINK/SOURCE OUTPUT
Sensed
Sensitivity
Mtg.
Supply
Supply
Current
Offset
mV&N*
Offset
Response
Catalog
Dim.
Volt.
Current
(Amps
Volt.
At 8 VDC
Shift
Time
Listing
Fig.
(Volts DC) (mA Max.) Peak)
(Volts±2%)
Nominal
± TOL
(%/
°
C)
(
µ
Sec.)
CSLA2GD
2a
6 to 12
20
72
Vcc/2
32.7
3.0
±.02
8
CSLA2GE
2a
6 to 12
20
92
Vcc/2
26.1
2.1
±.02
8
CSLA2GF
2a
6 to 12
20
125
Vcc/2
19.6
1.3
±.02
8
CSLA2GG
2a
6 to 12
20
150
Vcc/2
12.7
0.6
±.02
8
NOTE: When monitoring purely AC current with zero DC component, a capacitor can be inserted in series with the output of the current sensor. The capacitor will block
out the effect of the temperature variation of the offset voltage which increases the accuracy of the device.
*N = number of turns.
MOUNTING DIMENSIONS (for reference only)
Figure 1
Figure 1a
Figure 2
Figure 2a
* Application consideration: The out-
put is clamped at the high end. Clamp-
ing voltage may be as low as 9VDC.
The output will not exceed the clamp-
ing voltage regardless of field strength
or supply voltage.
Current
PDFINFO
p a g e - 0 5 9