•  Setting the target number (remote TA) 
at&z1=
XXX 
•  Setting the alarm text 
at*v 
common text for both alarms (collective message) 
at*v1 
individual text for alarm 1 
at*v2 
individual text for alarm 2 
-> NEW ALARMTEXT:
  Enter the new text: max. 160 characters for collective mes-
sage if the individual texts are empty, otherwise 120 char-
acters for collective message and 40 characters for each in-
dividual text. 
•  Setting the alarm function (optional) 
at*y2 
Connection will be terminated by deactivating the alarm 
input (only for alarm input 1) 
•  Storing the settings 
at&w 
Configuration of the remote ISDN TA 
•  Setting the MSN (own call number) 
at**msn=
xx 
xxx stands for the call number 
•  Setting the baud rate 
at%b
x stands for the selection of the respective baud rate, see 
chapter: Overview about the most important basic com-
mands 
•  Automatic call acceptance 
ats0=1
 
Call acceptance after first ring 
•  Storing the settings 
at&w