6.1 Electrical installation 
 
Connection of the inputs and outputs 
Make sure that the GSM module is disconnected from any power supply. Then you 
can start to connect the device with your application and external devices. 
 
The  wiring  of  the  analog  inputs  and  digital  inputs  and  outputs  depends  on  the  re-
spective  use.  Please  refer  to  chapter  "Description  of  the  Interfaces"  for  voltage 
limitations.  Please  contact  the  manufacturer  if  there  are  any  questions  or  need  for 
support regarding special solutions for your application. 
 
Power supply 
As power supply any DC source and AC/DC adapter with regulated output can be 
used.  The  rating  during  normal  use  is  max.  300  mA  (with  emergency  battery  1  A). 
The allowed range of the power supply voltage is indicated on the type identifica-
tion label
 
Serial interface 
For  the  configuration  of  the  module  you  need  the serial  cable  that  is  delivered  with 
the module. By connecting the device to the D Sub 9 connector of the COM- port of 
your computer you are able to do the configuration. 
Installation with optimal electromagnetic compatibility (EMV) 
It  is  recommended  to  ground  the  GSM  module  using  the  ground  connector  of  the 
device.  All  inputs  and  outputs  as  well  as  the  power  supply  should  lead  through  a 
ferrite to suppress any electromagnetic influences. 
 
 
7. Connection of the accumulator 
 
The emergency accumulator has to be connected with the correct polarity. 
 
 
Incorrect connection of the accumulator leads to a high risk of 
battery leakage of both gas and acid. As well the accu may be 
overheated and cause an ignition.