GSM Alarm & Telemetry systems
6.1 Electrical installation
Connection of the inputs and outputs
Make sure that the GSM module is disconnected from any power supply. Then you
can start to connect the device with your application and external devices.
The wiring of the analog inputs and digital inputs and outputs depends on the re-
spective use. Please refer to chapter "Description of the Interfaces" for voltage
limitations. Please contact the manufacturer if there are any questions or need for
support regarding special solutions for your application.
Power supply
As power supply any DC source and AC/DC adapter with regulated output can be
used. The rating during normal use is max. 300 mA (with emergency battery 1 A).
The allowed range of the power supply voltage is indicated on the type identifica-
tion label.
Serial interface
For the configuration of the module you need the serial cable that is delivered with
the module. By connecting the device to the D Sub 9 connector of the COM- port of
your computer you are able to do the configuration.
Installation with optimal electromagnetic compatibility (EMV)
It is recommended to ground the GSM module using the ground connector of the
device. All inputs and outputs as well as the power supply should lead through a
ferrite to suppress any electromagnetic influences.
7. Connection of the accumulator
The emergency accumulator has to be connected with the correct polarity.
Incorrect connection of the accumulator leads to a high risk of
battery leakage of both gas and acid. As well the accu may be
overheated and cause an ignition.