GSM Alarm & Telemetry systems 
 
0h 0m 0s      /     1.1.2000  
Reports the current time and date. Not correct setted ex works. 
 
 
123456789 ABC
 
This is the numbering of the digital entrances. This is indicated in HEX
 
code. Please note: A = input 10, B = input 11 and C = input 12. 
 
 
DIGITAL INPUTS 
Here is reported the condition of the digital inputs. If unused or in rest they 
are on level “1”. If by a sensor the input is pulled to ground the level jumps 
to a “0”.  These conditions also have to be taken into account for the set-
tings in the connection settings.  
 
 Example
If you need to trigger a reaction after an event occurring on a digital input, 
you have to enter a “0” for this digital inputs in the connections settings.  
Please take into account that closing the switch or relay contact con-
nected to a digital input will set this input to “0”!
 
 
 
DIGITAL OUTPUTS 
By the “connection settings” the digital outputs become corresponding to an 
“event” or a combination of several “events”. If this happens the level of the 
digital output jumps from “0” to “1” and switches the corresponding relay 
output. 
 
 
TIME FRAMES 
If a time frame is defined and is used in the connection settings, a “1” ap-
pears in the connection settings as long as this time period is active. A 
maximum of 3 time frames is possible to be defined. 
 
 
INCOMING SMS 
If a SMS is coming in and is recognised by the module, the level indicating 
this SMS indication changes from “0” to “1”.  
 
 
ANALOG INPUTS
 
In the settings for the analog inputs you are able to set a minimum and a 
maximum value to define a range in which the input signal indicates an 
event. That means that the GSM module supervises the input and has a