Note that for the example of a Wiremap test shown above; if the 
option ‘XOver Allowed’ had been checked 
in the Wiremap SETUP options, the results would be displayed as shown in Fig 22 and Fig 23. 
 
 
Fig 22 
 
Fig 23 
 
The wiremap tests may be run with no termination 
– open, or with an Active Remote termination.  When 
connected, an image of an Active Remote will be shown on the display and its type identified.  After a test 
has been run, the length of the cable is displayed (range up to 100m (330ft)). 
With an open termination the possible faults detected are: 
 
 
Fig 24  Open circuit by pair 
 
Fig 25  Short circuit by pin