Техническая Спецификация для Atmel Evaluation Kit for AT32uC3A0512, 32-Bit AVR Microcontroller Atmel ATEVK1105 ATEVK1105

Модели
ATEVK1105
Скачать
Страница из 826
311
AT32UC3A
26.7.3.2
Manchester Encoder
When the Manchester encoder is in use, characters transmitted through the USART are
encoded based on biphase Manchester II format. To enable this mode, set the MAN field in the
MR register to 1. Depending on polarity configuration, a logic level (zero or one), is transmitted
as a coded signal  one-to-zero or zero-to-one. Thus, a transition always occurs at the midpoint of
each bit time. It consumes more bandwidth than the original NRZ signal (2x) but the receiver has
more error control since the expected input must show a change at the center of a bit cell. An
example of Manchester encoded sequence is: the byte 0xB1 or 10110001 encodes to 10 01 10
10 01 01 01 10, assuming the default polarity of the encoder
illustrates
this coding scheme.
Figure 26-8.
NRZ to Manchester Encoding
The Manchester encoded character can also be encapsulated by adding both a configurable
preamble and a start frame delimiter pattern. Depending on the configuration, the preamble is a
training sequence, composed of a pre-defined pattern with a programmable length from 1 to 15
bit times. If the preamble length is set to 0, the preamble waveform is not generated prior to any
character. The preamble pattern is chosen among the following sequences: ALL_ONE,
ALL_ZERO, ONE_ZERO or ZERO_ONE, writing the field TX_PP in the MAN register, the field
TX_PL is used to configure the preamble length
illustrates and defines
the valid patterns. To improve flexibility, the encoding scheme can be configured using the
TX_MPOL field in the MAN register. If the TX_MPOL field is set to zero (default), a logic zero is
encoded with a zero-to-one transition and a logic one is encoded with a one-to-zero transition. If
the TX_MPOL field is set to one, a logic one is encoded with a one-to-zero transition and a logic
zero is encoded with a zero-to-one transition.
NRZ
encoded
data
Manchester
encoded
data
1
0
1
1
0
0
0
1
Txd
32058K