Figure 26-15.
Preamble Pattern Mismatch
Figure 26-16.
Manchester Error Flag
When the start frame delimiter is a sync pattern (ONEBIT field at 0), both command and data
delimiter are supported. If a valid sync is detected, the received character is written as RXCHR
field in the RHR register and the RXSYNH is updated. RXCHR is set to 1 when the received
character is a command, and it is set to 0 if the received character is a data. This mechanism
alleviates and simplifies the direct memory access as the character contains its own sync field in
the same register.
As the decoder is setup to be used in unipolar mode, the first bit of the frame has to be a zero-to-
one transition.
26.7.3.6
Radio Interface: Manchester Encoded USART Application
This section describes low data rate RF transmission systems and their integration with a Man-
chester encoded USART. These systems are based on transmitter and receiver ICs that support
ASK and FSK modulation schemes.
The goal is to perform full duplex radio transmission of characters using two different frequency
carriers. See the configuration in 
.
Manchester
encoded
data
Txd
SFD
DATA
Preamble Length is set to 8
Preamble Mismatch
invalid pattern
Preamble Mismatch
Manchester coding error
Manchester
encoded
data
Txd
SFD
Preamble Length
is set to 4
Elementary character bit time
Manchester
Coding Error
detected
sampling points
Preamble subpacket
and Start Frame Delimiter
were successfully
decoded
Entering USART character area
32058K