Техническая Спецификация для Sanyo PDA rechargeable battery replaces original battery 20-00598-04A WD, 0511-021087, 35-00097-02A 3.7 V 900 mAh 123771
Модели
123771
Document NO.:
WI-FHF-CS-N30SL-A
Page 4of 9
MODEL:
CS-N30SL
REV: A/1
Notes(
):
1. Period of storage is counted from shipping date
2.
Test Method and standard listed as below, environment temperature (15 25) , CC/CV
mode, 0.2C constant current charge to 4.2V, then constant voltage charge mode, cut off
current 0.01C 0.2C constant current discharge, cut off voltage 3.0V more than 5 hours
discharging time.
(15 25) ,CC/CV
,0.2C
4.2V,
,
0.01C
0.2C
,
3.0V
5
3.Test (
)
3.1 Testing Environment
:
3.1.1 Test time should be no more than one month after receive the battery
1
.
3.1.2 Testing Environment(
):
Humidity(
): 15 --25
Relative Humidity(
): 45%--85%
Atmospheric Pressure(
):
76
kPa--106kPa
3.2 Testing Instrument(
):
3.2.1 Voltage meter 0.5 grade or more regulated by IEC 51/IEC 485, more than 10KΩ/V
internal resistance
IEC 51/IEC 485
0.5
,
10KΩ/V
3.2.2 Current meter 0.5 grade or more regulated by IEC 51/IEC 485, include wire resistance
less than 0.01Ω.
IEC 51/IEC 485
0.5
,
0.01Ω.
3.2.3 Calipers Definition 0.02mm
0.02mm
3.2.4 Internal Resistance Meter AC 1KHz 4 terminal measure setting.
1KHz 4
.
3.2.5 Load Resistance
Include external circuitry, allowed resistance figure error is ±5%.
,
±5%.
3.2.6 Finished Battery Product Testing Machine