Справочник Пользователя для Texas TMS320C645X

Скачать
Страница из 218
www.ti.com
SRIO Registers
Table 138. Port Control Independent Register (SPn_CTL_INDEP) Field Descriptions (continued)
Bit
Field
Value
Description
17
MAX_RETRY_EN
Max_retry_error report enable. If enabled, the Port-Write and interrupt are reported as errors.
1b
Max retry error report enable
0b
Max retry error report disable
16
MAX_RETRY_ER
Max_retry_error bit is set when max_retry_cnt is equal to max_retry_threshold. The Port-Write
R
request and interrupt are generated if enabled. This bit is ignored if max_retry threshold is 00. Once
set, it remains set until written with logic 1 to clear. This bit also is cleared by writing all 0s to the
register SP0_ERR_DET. This error also reported in register SP0_ERR_DET.
15-8
MAX_RETRY_TH
Maximum Retry Threshold Trigger. These bits provide the threshold value for reporting an error
R
condition due to possibly broken partner behavior.
00
Disable the max_retry_error reporting
01
Set the max_retry_threshold to 1
02
Set the max_retry_threshold to 2
...
FF
Set the max_retry_threshold to 255
7
IRQ_EN
Interrupt error report Enable. If enabled, the interrupt signal is High when the IRQ_ERR is set to 1.
1b
Interrupt error report enable
0b
Interrupt error report disable
6
IRQ_ERR
The Interrupt Error Status bit. It is set to one if an error occurs and there is a Port-Write condition.
Once set, remains set until written with logic 1 to clear.
5-0
Reserved
Reserved
Serial RapidIO (SRIO)
214
SPRU976 – March 2006