Справочник Пользователя для Inline Warehouse IN60000

Скачать
Страница из 25
11
1995-1997 - INLINE, INC
PATHFINDER OPERATION MANUAL - REV2.1A      May 19, 1997
The following screen will appear (although it may appear different for your unit if it is already set for a
baud rate other than 1200):
The asterisk, 
*
, in the bottom right hand corner of the display indicates that this baud rate is currently
selected.  To view the other rates available, press the NEXT button, and the baud rate will change to the
next highest rate, which would be 
2400bps
 for this example.  You will notice that there is no asterisk for
2400, as this in not the current baud rate the PATHFINDER is set to use.  Pressing the NEXT button again
will increase the baud rate to 
4800bps
, then 
9600bps
, then 
19200bps
, and then back to
1200bps
.  When the desired baud rate is displayed, you can select it or exit with no change as follows:
MENU:
Pressing the MENU button exits this section with no change.
ENTER/SELECT:
Pressing the ENTER/SELECT button will temporarily store the Baud Rate setting until the power is
turned off.  Upon re-applying power to the PATHFINDER, the Baud Rate will return to its
previously saved setting.
SAVE/RECALL:
Pressing the SAVE/RECALL button will save the Baud Rate setting in memory and will use it every
time the unit is powered on.  This setting will remain until you re-program the unit to Save a different
setting or reset the PATHFINDER to Factory Default (see Power On Settings on page 13 for more
details).
COMMAND Code:
The COMMAND Code section allows you to choose the leading and ending characters of the actual
protocol which the PATHFINDER will respond to.  By choosing different Command Codes for multiple
units, up to four PATHFINDERs can be controlled independently with one RS-232 serial port (Note: A RS-
232 distribution amplifier must be used.)  If you are not using a remote control device, such as a PC or a
third party remote control system, you can ignore this section.  Enter this section by pressing the
ENTER/SELECT button when the screen reads as follows: