WARNING
!
FIRE HAZARD
•  Do not exceed the specified voltage.
•  Replace  existing  control  with  exact  model  and
dash number.
•  Protect the control from direct contact with water
(dripping, spraying, rain, etc.).
•  If the control has been in direct contact with water,
replace the control.
•  Label all wires before disconnection when servic-
ing controls. Wiring errors can cause improper and 
dangerous operation.
•  Route and secure wiring away from flame.
SHOCK HAZARD
•  Disconnect electric power before servicing.
•  Ensure proper earth grounding of appliance.
•  Ensure proper connection of line neutral and line
hot wires.
EXPLOSION HAZARD
•  Shut off main gas to appliance until installation is
complete.
 
 INSTALLATION
CAUTION
!
Do  not  short  out  terminals  on  gas  valve  or  primary
control. Short or incorrect wiring may damage the 
thermostat.
REPLACING 10M9301, 12L6901, 32M8801, 
50A65-120, 50A65-121 or 56L8401
1.  Disconnect all electrical power and shut off the gas 
supply to the furnace.
2.  Remove the access panel.
3.  Disconnect wiring and remove existing ignition 
control board from the control box.
4.  Install provided circuit breaker in unit control box 
or secure circuit breaker to a wire harness using 
wire ties.
5.  Position the provided mounting panel with the 
arrow on the front of the panel pointing up. Position 
the replacement 50A66-843 ignition control board 
over the holes marked "A" in figure 1. Insert the 
replacement control stand-off fasteners into the 
holes in the mounting panel.
6.  Insert the four provided stand-off fasteners into the 
back of the mounting panel in the holes marked "B" 
in figure 1. Insert the replacement control board 
assembly into the existing holes in the control box 
or blower panel.
7.  Insert provided circuit breaker in series between the 
blue transformer wire connecting position 3 on the 
12-pin connector to the transformer (TH), optional 4" 
blue wire provided for transformers that have a quick-
connect terminal.
8.  Connect the remaining 120 VAC hot and neutral wires 
and the flame sense wire to the replacement control 
per table 1, page 4. 
9.  Affix wiring diagram 5001-6973 adjacent to the 
existing unit wiring diagram.
10.  Replace the access panel.
11.  Restore the electrical power and gas supply. Refer 
to the furnace installation instructions for start-up 
and check-out procedures.
PROCEDURE 1
B                         B
B                          B
A                       A  
A                                A  
C
C
C
C
Arrow on
front of panel
Figure 1 – Mounting Panel
Photo 1
MOUNTING PANEL
The Mounting Panel is required in Procedure 1 and Proce-
dure 2. It will become part of the installation for Procedure 
1. It will be used as a template for locations to drill holes 
in Procedure 2, Step 4A and 4B. It will become part of 
the installation in Procedure 2, Step 4C.
Mounting panel
Circuit breaker
in series between 
Pin 3 and 
Transformer (TH)
Optional 4" blue 
wire to connect to 
Transformer (TH)