SERVICE (cont.)
LAMP CORD ASSY
FIG. 37 LAMP CORD ASSY
P1343
Location:
The lamp cord assembly is located in the left top 
of the auger motor cover.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Unplug the lamp cord assembly from lamp cord 
connector assembly.
3.  Check for continuity across the tip of the cord as-
sembly and the housing. Continuity must not be 
present when both lamps are removed.
If continuity is present as described, the cord assembly 
is operating properly.
If continuity is not present as described, replace the 
cord assembly.
Removal and Replacement:
1.  Disconnect the lamp cord assembly from the lamp 
cord connector assembly in the top of the auger 
motor cover.
2.  Remove the hopper cover with the lamp cord as-
sembly from the hopper.
3.  Remove  hopper  cover  liner  from  the  hopper 
cover.
4.  Cut the closed splice terminals connecting lamp 
cord assembly to the lamp holder/socket assembly 
off.
5.  Remove lamp cord assembly from hopper cover 
and discard.
6.  Push new lamp cord wires through the holes on 
the left outside top of the hopper cover.
7.  Strip  the  wires  from  the  lamp  holder/socket  as-
sembly approximately .375”.
8.  Using the two wire nuts, supplied, connect the new 
lamp cord assembly to the lamp holder/socket as-
sembly wires.
9.  Reinstall the hopper liner to the bottom of the hop-
per cover.
10. Reinstall the hopper cover to the hopper.
11. Plug in the new lamp cord assembly to the lamp 
cord connector assembly on left top of the auger 
motor cover.
12. Refer to Fig. 38 when reconnecting the wires.
FIG. 38 LAMP CORD WIRES
P1332
27646 122200