SERVICE (cont.)
LAMP CORD CONNECTOR
If continuity is not present when lamp cord assembly 
is connected or continuity is present when lamp cord 
assembly  is  not  connected,  replace  the  lamp  cord 
connector.
Removal and Replacement:
1.  Disconnect the lamp cord assembly from the lamp 
cord connector.
2.  Remove the two #8-32 locking screws securing the 
auger motor cover the auger motor bracket/cooling 
drum bracket. Move cover back far enough to gain 
access to the lamp cord connector.
3.  Disconnect the lamp cord connector wires from 
the dispenser main wiring harness.
4.  Remove nut and washer securing the lamp cord 
connector to the auger motor cover and discard 
nut, washer and lamp cord connector.
5.  Remove new nut and washer from new lamp cord 
connector.
6.  Push new lamp cord connector through the hole 
in the auger motor cover and secure with the new 
nut and washer.
7.  Reconnect the wires on the cord connector to the 
dispenser main wiring harness.
8.   Position auger motor cover on auger motor bracket/
cooling drum bracket and secure with two #8-32 
locking screws.
9.  Refer to Fig. 40 when reconnecting wires.
FIG.40 LAMP CORD CONNECTOR
P1323
FIG. 39 LAMP CORD CONNECTOR
P1343
Location:
The lamp cord connectors are located inside the 
upper left side of the auger covers.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the plug on the dispenser main harness 
from the connector from the lamp cord connec-
tor.
3.   With a voltmeter, check the voltage across the two 
pin holes on the main harness plug  and DAY/NIGHT 
switch “-” in the down position and the ON/OFF 
switch in the “ON” position. Connect the dispenser 
to the power source. The indication must be ap-
proximately 12.6 volts dc.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the 
Wiring Diagram and check the dispenser main wiring 
harness.
NOTE: Lamp cord assembly (Fig. 37) and lamps, must 
be tested and determined to be functioning properly 
before proceeding to step 5.
5.  Check for continuity across the black wire pin and  
red wire  pin of the lamp cord connector (Fig. 40). 
Continuity must be present when the lamp cord 
assembly is connected and must not be present 
when lamp cord assembly is disconnected from 
lamp cord connector.
27646 122200
BLK to Main Wiring Harness