SERVICE (cont.)
L.E.D./ADJUSTMENT BOARD
3.  Lift  switch  panel  with  wires  and  L.E.D.  /adjust-
ment 
 
board as an assembly and turn over.
4.  Disconnect the connector on the dispenser wiring 
harness from the pin connector on the rear of the 
L.E.D./adjustment board.
5.  Remove the #4 keps nut from the right rear stud 
on the control panel and remove the green ground 
wire.
6.   Remove the remaining five #4 keps nuts from the 
studs on the control panel.
7.  Remove the #6 stainless steel washer and the #6 
nylon washer from the front stud on the control 
panel.
8.  Remove board and discard.
9.  Position a new board on the studs and spacers.
10. Install the #6 nylon washer and the #6 stainless 
steel washer on the front stud of the control panel. 
Be sure the nylon washer is installed first.
11. Secure the new board to the control panel using 
five #4 keps nuts.
12. Connect the green lead from the dispenser main 
harness to the right rear stud of the control panel 
and secure with a #4 keps nut.
13. Reconnect the connector from the dispenser main 
wiring harness to the pin connector at the rear of 
new L.E.D./adjustment board.
14. Turn board and panel over and position in the dis-
penser drawer and secure with four #8-32 locking 
screws.
FIG. 43 L.E.D./ ADJUSTMENT BOARD
P1343
Location:
The L.E.D./adjustment board is located in the dis-
penser drawer attached to the bottom of the control 
panel.
Test Procedures:
1.   Disconnect the dispenser from the power source.
2.  Disconnect the connector at the rear of the L.E.D./
adjustment board from the dispenser main wiring 
harness.
3.  With a voltmeter, check the voltage between pin hole 
#1 (black wire) and pin hole #8 (pink wire)  with 
the ON/OFF switch in the “ON” position. Connect 
the dispenser to the power source. The indication 
must be 5 volts dc.
4.   Disconnect the dispenser from the power source.
If voltage is present as described, replace the L.E.D./
adjustment board.
If voltage is not present as described, refer to the Wiring 
Diagram and check the dispenser wiring harness.
Removal and Replacement:
1.  Pull the dispenser drawer out far enough to expose 
the four #8 -32 locking screws securing the switch 
panel to the drawer.
2.  Remove the four #8-32 locking screws.
27646 122200