Note: For finishing to top of fireplace, refer to Figure 13.
Figure 12
Attention:  Add  3-3/4"  to  “A”  dimensions  when  using  a  flush 
mantel base.
Attention: If a base or mantel is not used and the appliance is 
installed directly on carpeting, tile or other combustible material 
other than wood flooring, it shall be installed on a metal or wood 
panel extending the full width and depth of the appliance. The 
vertical dimension in Figure 12 must be adjusted when a metal or 
wood panel is placed beneath the appliance.
Finishing (Figures 13 and 14)
Finish  the  walls  with  the  material  of  your  choice.  Figure  3  on 
page 9 shows the minimum vertical and corresponding maximum 
horizontal dimensions of mantels or other combustible projections 
above the top front edge of the fireplace.
Only non-combustible materials may be used to cover the black 
fireplace front.
Caution: If the joints between the finished wall and the fireplace 
surround  (top  and  sides)  are  sealed,  a  300°F  minimum  sealant 
material must be used. These joints are not required to be sealed. 
Only non-combustible material (using 300°F minimum adhesive if 
needed), can be applied as facing to the fireplace surround.
Flush Mount Mantel Installation (Figure 11)
The fireplace must extend 3/4" beyond finished wall surface when 
using a flush mount mantel. Refer to Figure 11 to locate nailing 
flanges on fireplace sides. Mark and drill two (2) 1/8" holes into 
fireplace  side  to  mount  each  nailing  flange.  Use  eight  (8)  1/2" 
hex-head screws supplied in hardware package to attach nailing 
flanges to fireplace sides.
Figure 11
Attention: When fireplace is installed in optional full cabinet mantel 
or corner mantel the (4) four nailing flanges shown in Figure 11 will 
not be installed on the side of outer casing. The fireplace will be 
attached to the full cabinet mantel or corner mantel with the (2) two 
nailing flanges located on the top of the outer casing assembly.
Framing (Figure 12)
Fireplace framing can be built before or after the fireplace is set in 
place. Framing should be positioned to accommodate wall covering 
and  fireplace  facing  material.  The  fireplace  framing  should  be 
constructed of 2 x 4 lumber or heavier. The framing headers may 
rest on the fireplace standoffs. Refer to Figure 12 for minimum 
framing dimensions.
CAUTION:  MEASURE  FIREPLACE  DIMENSIONS AND 
VERIFY FRAMING METHODS, AND WALL COVERING 
DETAILS  BEFORE  FRAMING  CONSTRUCTION 
BEGINS.
NAIL OR OTHER SUITABLE FASTENER
INSTALLATION (continued)
Framing dimension "A" includes a three inch clearance for 
standoffs on firebox. After installing firebox into framing, 
the finished wall surface must cover the three inch opening 
above the firebox.
DVD32
DVD36
DVD42
DVD48
"A"
35 3/4"
(908 mm)
35 3/4"
(908 mm)
37 3/4"
(959 mm)
37 3/4"
(959 mm)
"B"
34 3/8"
(873 mm)
37 3/8"
(949 mm)
43 3/8"
(1102 mm)
49 3/8"
(1254 mm)
"C"
16 3/8"
(416 mm)
16 3/8"
(416 mm)
16 3/8"
(416 mm)
16 3/8"
(416 mm)
Warning:  When  finishing  the  fireplace  never  obstruct 
or  modify  the  air  inlet/outlet  louvers  in  any  manner. 
Provide adequate clearances around air openings into the 
combustion chamber.