Flush Wall Installation
Figure 13
Combustible Surround Installation
Figure 14
Attention:  Cold  climate  installation  recommendation: 
When installing this unit against a non-insulated exterior 
wall, it is recommended that the outer walls be insulated to 
conform to applicable insulation codes.
Vent Runs (Figures 15, 16, 17, 18 and 19)
In planning the installation for the fireplace, it is necessary to install 
certain components before the appliance is completely positioned 
and installed. These include the direct vent system, gas piping for the 
appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry 
blocks.) These supports must be positioned so they contact all 
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL 
TERMINATION
Figure 15
3! OF NON-COMBUSTIBLE MATERIAL
FINISHED WALL
FRONT TRIM OR NON-
COMBUSTIBLE MA TERIAL
(INSTALLA TION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
DVD32, 36
47 ½”
(121 cm)
TO BOTTOM
OF UNIT
DVD42, 48
49 ½”
(126 cm)
TO BOTTOM
OF UNIT
VENTCAP/
THIMBLE
3! OF NON-COMBUSTIBLE MATERIAL
FINISHED WALL
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
INSTALLATION (continued)