The conversion shall be carried out in accordance with the 
requirements of the provincial authorities having jurisdiction 
and in accordance with the requirements of the CSA B149.2 
installation code (Canada) and with the requirements of the 
National Fuel Gas Code Z223.1/NFPA 54 (United States).
WARNING:  This  conversion  kit  shall  be  installed  by  a 
qualified service agency in accordance with the manufacturer's 
instructions  and  all  applicable  codes  and  requirements 
of  the  authority  having  jurisdiction.  If  the  information  in 
this instruction is not followed exactly, a fire, explosion, or 
production of carbon monoxide may result causing property 
damage, personal injury, or loss of life. The qualified service 
agency is responsible for the proper installation of this kit. 
The installation is not proper and complete until the operation 
of  the  converted  appliance  is  checked  as  specified  in  the 
manufacturer's instructions supplied with the kit.
Installer notice: Using an ink pen, fill out the required information 
on the conversion label. Remove the backing from label and stick 
label  in  a  visible  position  on  bottom  of  fireplace  close  to  gas 
valve.
Installer  notice:  These  instructions  must  be  left  with  the 
appliance.
Instructions for converting your direct ignition fireplace from 
natural gas to propane/LP gas.
All direct ignition fireplaces are shipped from the factory equipped 
to operate on natural gas. To convert the direct ignition fireplace 
to operate on propane/LP gas, follow the instructions on Page 
47. Please see the appropriate parts list for your model for parts 
included with the direct ignition fireplace.
Check the items in the kit with the parts list. Notify the supplier of 
any items that are missing before installing the conversion kit.
1.  Turn off the gas supply.
2.  Turn  off  the  electrical  supply  to  the  appliance  if  so 
equipped.
3.  Remove top louver and lower bottom louver.
4.  Remove glass frame assembly.
5.  Remove logs from burner assembly.
VALVE CONVERSION
6.  Remove plastic cap from regulator fitting. Unscrew fitting 
using a 7/16" wrench. Turn fitting over so end of fitting marked 
"LPG" (red) screws into valve. Tighten fitting (snug only). 
Replace plastic cap.
7.  Remove 1/4" screw from air shutter.
8.  Located to the right of electrodes is a burner hold-down tab. 
Using needle-nose pliers, bend burner hold-down tab off the 
main burner. 
9.  Remove main burner by pivoting main burner forward as you 
slide main burner from left to right. Be careful as you remove 
main burner in order to protect the electrodes from being 
damaged.
10.  Remove air shutter from orifice fitting.
11.  Remove natural gas main burner orifice from orifice fitting.
DIRECT IGNITION PROPANE/LP GAS CONVERSION
12.  Install  propane/LP  main  burner  orifice  marked  #56  for 
DVD32FP50, marked #55 for DVD36FP50, marked 1.45 mm 
for DVD42FP50 or marked #52 for DVD48FP50.
 
Important:  Failure to install the correct orifice will result in 
unit over-firing that could overheat the appliance and result 
in a fire.
13.  Replace air shutter onto orifice fitting. Air shutter must be 
threaded and bottomed-out onto orifice fitting.
14.  Replace main burner onto burner assembly. Place main burner 
beneath electrodes, slide main burner from right to left into 
burner location, and pivot main burner away from you and 
into air shutter.
15.  Set air shutter opening at 1/4" for DVD32 or DVD36 and 
5/16" for DVD42 or DVD48. Tighten air shutter in place 
with 1/4" screw from step 7.
16.  Using  needle-nose pliers, bend burner hold-down tab over 
main burner.
17.  Refer to log placement, pages 36 and 37 to place logs onto 
burner assembly.
18.  Loosen screw and attach a manometer or pressure gauge to 
the outlet pressure tap of the control valve. 
19.  Turn  on  the  gas  supply. Turn  on  the  electrical  supply  to 
the appliance. Check for gas leaks using soap and water 
solution or leak detection solution. Bubbles indicate a leak 
that MUST be corrected. Do not use an open flame to test 
for gas leaks.
20.  Check  the  air  shutter  opening.  See  chart  and  illustration 
below.
21.  Relight the main burners and verify proper burner ignition 
and operation.
22.  With  the  main  burner  burning,  read  the  pressure  on  the 
manometer or pressure gauge. The pressure on the gauge 
should read between 9.8" and 10.2" w.c.
23.  Turn off the gas supply. Turn off the electrical supply to the 
appliance. 
24.  Remove the manometer or pressure gauge. Tighten the screw 
in the pressure tap.
25.  Turn on the gas supply. Turn on the electrical supply to the 
appliance. 
26.  Immediately test all gas line connections and the control 
valve for gas leaks using a soap and water solution or other 
gas detection solution. Bubbles indicate a leak that MUST be 
corrected. Do not use an open flame to test for gas leaks. 
27.  Using a ball point pen, fill out the conversion label that is 
supplied with the conversion kit. Place the conversion label 
adjacent to the rating plate. 
28.  Replace glass frame assembly.
29.  Reinstall top and bottom louvers. 
30.  Test operation of fireplace once again. Allow the fireplace to 
operate for at least 10 minutes and check flame coloration. 
Flames  on  rear  of  burner  should  be  yellow  without  any 
orange-colored tip. Minor adjustment of the air shutter may 
be necessary to "tune in" the proper flame color.