Справочник Пользователя для White Mountain DIRECT IGNITION DVD32FP5(0,1,2,3)N-2

Скачать
Страница из 60
23552-5-0608
Page 7
Remote Control Options 
& Accessories
Description
FRBC
Millivolt Battery Remote ON/OFF
FRBTC
Millivolt Battery Remote Thermostat
FREC
Direct Ignition/Millivolt 120V ON/OFF Remote
TMW
Millivolt Wireless Wall Thermostat
TRW
Millivolt Reed Switch Wall Thermostat
FWS-1
Direct Ignition/Millivolt Wall Switch
Venting Options
Description
DVVK-4TSP
(DVVK-4TS)
Top vent kit (horizontal) - 4½" to 6" (114.3 mm to 152 mm) wall thickness
DVVK-4TP
(DVVK-4T)
Top vent kit (horizontal) - 8" to 12" (203 mm to 305 mm) wall thickness
DVVK-4RP
(DVVK-4R)
Rear vent kit (horizontal) - 5" to 7" (127 mm to 178 mm) wall thickness
DVVK-4VP
(DVVK-4V)
Vertical vent kit 
DVVK-4F
Horizontal flex vent kit (4' FLEX)
DVVK-4RE
Horizontal round termination (wall thickness up to 11 7/16")
DV822
Vinyl siding kit for DVVK-4RE
DVD32
DVD36
DVD42
DVD48
Input BTU/Hr Maximum
18,000
20,000
25,000
28,000
         BTU/Hr Minimum (millivolt only)
14,000
14,000
18,000
20,000
KWH (Maximum)
5.3
5.9
7.3
8.2
          (Minimum)
4.1
4.1
5.3
5.9
NAT.
Orifice
#46 (.081")
P-254
2.10 mm
P-288
#42 (.0935")
P-286
#39 (.0995")
P-285
Air Shutter Opening
1/16" (1.6 mm)
1/16" (1.6 mm)
3/16"(4.8 mm)
1/8" (3.2 mm)
LP
Orifice
#56 (.0465")
P-287
#55 (.052")
P-182
1.45 mm
P-208
#52 (.0635")
P-185
Air Shutter Opening
1/4" (6.3 mm)
5/16" (7.9 mm)
5/16" (7.9 mm)
5/16" 
(7.9 mm)
Height without standoff
32 3/4" (832 mm)
32 3/4"(832 mm)
34 3/4"(883 mm)
34 
3/4"(883 mm)
Width
34" (864 mm)
37" (940 mm)
43" (1092 mm)
49" 
(1245 mm)
Depth
16 3/8" (416 mm)
16 3/8" (416 mm) 16 3/8" (416 mm)
16 3/8" 
(416 mm)
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2NPT
NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air 
shutter adjustments for optimum performance.
SPECIFICATIONS