The baud rate cannot be set 
using the Change Baud Rate 
Wizard or the Brother 
PT-9500PC utilities.
Error 99: the personal computer 
cannot detect the PT-9500PC.
Make sure that the PT-9500PC is turned 
on.
Make sure that the interface cable is 
connected correctly.
Make sure that the COM port where the 
PT-9500PC is connected is the same 
COM port selected in the Change Baud 
Rate Wizard. (Many personal computers 
have more than one COM port and 
COM2 may have been selected in error 
in the Change Baud Rate Wizard.)
Make sure that the USB interface cable 
is not connected to the PT-9500PC 
during a serial connection.
Error 1 or Error 5: the serial port 
of the personal computer cannot 
be used.
When another serial connection device 
is using the same COM port for 
Windows
®
 NT 4.0/2000 Pro/XP, labels 
cannot be printed. Change the COM 
port for the serial connection device or 
connect the PT-9500PC to a COM port 
that is not being used.
Depending on the personal computer, 
the COM port may be turned off as a 
default at the factory. Refer to the 
instruction manual for the personal 
computer or contact the personal 
computer manufacturer to turn on the 
COM port.
<Check the COM port>
(For Windows
®
 95/98)
Double-click the System icon in Control 
Panel.
Click the Device Manager tab, and then 
click the plus sign next to Ports (COM & 
LPT)
• Make sure that COM1 and COM2 are 
listed.
• Make sure that there are no error 
symbols displayed.
The personal computer does not 
support the initial baud rate 
setting, 115,200 bps, of the 
PT-9500PC.
Some old personal computers may not 
support the initial baud rate setting, 
115,200 bps, of the PT-9500PC.
P.101). After changing the baud rate, 
 P.41) and 
change the baud rate to 57,600 bps or 
9,600 bps.
After the labels are cut, 
they are not ejected from 
the PT-9500PC 
correctly.
The cutter blade is dirty.
and clean the cutter.
Problem
Cause
Solution