4-6. Resetting all settings to their defaults 
If the sewing machine stops operating normally, the cause may be that an incorrect setting may have been made for the 
memory data by means of memory switches, for instance. In such cases, it may be possible to restore normal operation by 
following the steps given below to initialize the memory setting data. 
 
1.  While pressing the continuous backtack key, turn on the power switch. 
The mode wills witch to initialization mode and “1. ALL” will appear in the main display. 
2. Press the C       or D        key to select an item to be initialized. 
 
Main display 
Initialization item 
1.ALL 
Clear all 
2.MEM 
Memory switch initialization 
3.SPD 
Sewing speed initialization 
4.SEW 
Program initialization 
 
3.  Press the ENTER key for 2 seconds or more. 
Once initialization is complete, the main display will change to display “End”. 
4.  Press the FUNC key. 
Initialization mode will be exited and normal sewing machine operation will then be possible. 