Инструкции Пользователя для Bunn TU5Q
Page 12
TROUBLESHOOTING (cont.)
PROBLEM
PROBLEM
Weak beverage (cont.)
Dry tea leaves remain in the fun-
nel
Brewer is making unusal noises
PROBABLE CAUSE
4. Funnel Loading
5. Water Temperature
6. Low Brew Water Volume
1. Funnel Loading
1. Solenoid(s)
2. Plumbing Lines
3. Water Supply
4. Tank Heater
REMEDY
The BUNN
®
paper filter must be
centered in the funnel and the bed
of tea leaves leveled by gentle
shaking.
Place an empty funnel on an empty
dispenser beneath the sprayhead.
Initiate a brew cycle and check the
water temperature immediately be-
low the sprayhead with a thermom-
eter. The reading should not be
less than 200°F. Adjust the control
thermostat to increase the water
temperature. Replace if necessary.
Adjust needle valve to achieve 76
oz. water from the sprayhead when
the batch size setting is at three
gallons. To increase volume, turn
counter-clockwise. To decrease
volume, turn clockwise.
The BUNN
®
paper filter must be
centered in the funnel and the
bed of tea leaves leveled by gently
shaking.
The nut on the solenoid(s) must
be tight or it will vibrate during
operation.
Plumbing lines should not be rest-
ing on the counter top.
(A) The brewer must be connected
to a cold water line.
(B) Water pressure to the brewer
must not exceed 90 psi(621 kPa).
Install a regulator if necessary to
lower the working pressure to ap-
proximately 50 psi(345 kPa).
Remove and clean lime off the tank
heater. See page 22
10777 041500