Справочник Пользователя для WHP Wireless DL360

Скачать
Страница из 246
 Troubleshooting 
165 
 
Drive (Bay) X Firmware Needs Upgrading 
Description: Firmware on this physical drive is below the latest recommended 
version.  
Action: Run Options ROMPaq to upgrade the drive firmware to the latest 
revision. 
 
Drive (Bay) X has Insufficient Capacity for its Configuration 
Description: Drive has insufficient capacity to be used in this logical drive 
configuration. 
Action: Replace this drive with a larger capacity drive. 
 
Drive (Bay) X has Invalid M&P Stamp 
Description: Physical drive has invalid monitor and performance data. 
Action: Run the server setup utility to properly initialize this drive. 
 
Drive (Bay) X Has Loose Cable 
Description: The array controller could not communicate with this drive at 
power-up. This drive has not previously failed. 
Action
1.  Be sure all cables are properly connected and working. 
2.  Power up the system and attempt to reconnect data/power cable to the drive. 
3.  If the problem persists, replace the cable. 
4.  If the problem persists, replace the drive.