 Troubleshooting 
177 
 
Set Configuration Command Issued 
Description: The configuration of the array controller has been updated. The 
array accelerator board may remain disabled until it is reinitialized. 
Action: Run the server setup utility to reinitialize the array accelerator board. 
 
Soft Firmware Upgrade Required 
Description: ADU has determined that the controller is running firmware that 
has been soft upgraded by the Upgrade Utility. However, the firmware running is 
not present on all drives. This could be caused by the addition of new drives in 
the system. 
Action: Run the Upgrade Utility to place the latest firmware on all drives. 
 
Storage Enclosure on SCSI Bus X has a Cabling Error (Bus Disabled)... 
...SOLUTION: The SCSI controller has an internal and external cable attached to the same 
bus. Please disconnect the internal or external cable from the controller. If this controller 
supports multiple buses, the cable disconnected can be reattached to an available bus.  
Description: The current cabling configuration is not supported. 
Action: Refer to the server documentation for cabling guidelines, and 
reconfigure as indicated. 
 
Storage Enclosure on SCSI Bus X Indicated a Door Alert... 
...SOLUTION: Be sure that the storage enclosure door is closed or the side panel is properly 
installed.  
Description: The side panel of the external storage unit is open. 
Action: Be sure the side panel of the storage unit is securely closed. 
 
Storage Enclosure on SCSI Bus X Indicated a Power Supply Failure... 
...SOLUTION: Replace the power supply.