 Troubleshooting 
183 
 
4.  Repeat these steps with the other controller. 
If both controllers give POST messages in one slot but not the other, it is a 
system board problem. If one of the controllers gives POST messages and the 
other controller does not, replace the controller that is giving the POST 
messages. Contact an authorized service provider for any warranty replacements. 
 
This Controller Can See the Drives but the Other Controller Can't 
Description: The other controller in the redundant controller configuration 
cannot recognize the drives, but this controller can. 
Action: Resolve any other errors and then rerun ADU. 
 
The Redundant Controllers Installed are not the Same Model... 
...SOLUTION: Power down the system and verify that the redundant controllers are 
different models. If they are different models, replace the other controller with the same 
model as this one. 
Description: ADU detected two different controller models installed in a 
redundant controller configuration. This is not supported and one or both 
controllers may not be operating properly. 
Action: Use the same controller models for redundant controller configurations. 
 
This Controller Can't See the Drives but the Other Controller Can 
Description: The other controller in the redundant controller configuration can 
recognize the drives, but this controller cannot.  
Action: Resolve any other errors and then rerun ADU. 
 
Unable to Communicate with Drive on SCSI Port X, Drive ID Y 
Description: The array controller cannot communicate with the drive. 
Action: If the hard drive amber LED is on, replace the drive.