 Troubleshooting 
207 
 
 
  
  
 
 
40X-Parallel Port X Address Assignment Conflict 
Audible Beeps: 2 short 
Possible Cause: Both external and internal ports are assigned to parallel port X
Action: Run the server setup utility and correct the configuration. 
 
 
404-Parallel Port Address Conflict Detected... 
...A hardware conflict in your system is keeping some system components from working 
correctly. If you have recently added new hardware remove it to see if it is the cause of the 
conflict. Alternatively, use Computer Setup or your operating system to insure that no 
conflicts exist. 
Audible Beeps: 2 short 
Possible Cause: A hardware conflict in the system is preventing the parallel port 
from working correctly. 
Action
1.  If you have recently added new hardware, remove it to see if the hardware is 
the cause of the conflict. 
2.  Run the server setup utility to reassign resources for the parallel port and 
manually resolve the resource conflict. 
3.  Run Insight Diagnostics ("HP Insight Diagnostics" on page 
failed components as indicated. 
 