 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide 
 
Processor Uncorrectable Internal Error (Slot X, Socket Y) 
Event Type: Uncorrectable error 
Action: Replace the processor. 
 
Real-Time Clock Battery Failing 
Event Type: System configuration battery low 
Action: Replace the system configuration battery. 
 
System AC Power Overload (Power Supply X) 
Event Type: Power supply overload 
Action
1.  Switch the voltage from 110 V to 220 V or add an additional power supply 
(if applicable to the system). 
2.  If the problem persists, remove some of the installed options. 
 
System AC Power Problem (Power Supply X) 
Event Type: AC voltage problem 
Action: Check for any power source problems. 
 
System Fan Failure (Fan X, Location) 
Event Type: Fan failure 
Action: Replace the fan. 
 
System Fans Not Redundant 
Event Type: Fans not redundant 
 
  
  
Action: Add a fan or replace the failed fan.