Squelch Threshold Level
ˆ Inject a 435.100 MHz signal at a level of –14 dBµ
(with 1 kHz modulation @±3.5 kHz deviation)
from the RF signal generator.
ˆ Rotate the SQL knob to the 10-o’clock position.
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.100 tL
435.100 tL
435.100 tL
435.100 tL
435.100 tL.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “Squelch Threshold Level.”
ˆ Press the [D/MR(MW)] key three times.
ˆ Press the [D/MR(MW)] key.
S-meter Level (S-1)
ˆ Inject a 435.100 MHz signal at a level of –5 dBµ
(with 1 kHz modulation @±3.5 kHz deviation)
from the RF signal generator.
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.100 S1
435.100 S1
435.100 S1
435.100 S1
435.100 S1.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “S-meter Level (S-1).”
ˆ Press the [D/MR(MW)] key three times.
ˆ Press the [D/MR(MW)] key.
S-meter Level (S-9)
ˆ Inject a 435.100 MHz signal at a level of +23 dBµ
(with 1 kHz modulation @±3.5 kHz deviation)
from the RF signal generator.
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.100 S9
435.100 S9
435.100 S9
435.100 S9
435.100 S9.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “S-meter Level (S-9).”
ˆ Press the [D/MR(MW)] key three times.
ˆ Press the [D/MR(MW)] key.
TX Power (High)
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 HP
435.000 HP
435.000 HP
435.000 HP
435.000 HP.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “TX Power (High).”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the RF Power Meter
reading is 50 W (±1.0W).
ˆ Press the [D/MR(MW)] key.
TX Power (Low 3)
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 L3
435.000 L3
435.000 L3
435.000 L3
435.000 L3.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “TX Power (Low 3).”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the RF Power Meter
reading is 25 W (±1.0 W).
ˆ Press the [D/MR(MW)] key.
TX Power (Low 2)
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 L2
435.000 L2
435.000 L2
435.000 L2
435.000 L2.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “TX Power (Low 2).”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the RF Power Meter
reading is 10 W (±0.5 W).
ˆ Press the [D/MR(MW)] key.
TX Power (Low 1)
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 L1
435.000 L1
435.000 L1
435.000 L1
435.000 L1.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “TX Power (Low 1).”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the RF Power Meter
reading is 5 W (±0.5 W).
ˆ Press the [D/MR(MW)] key.
TX Deviation
ˆ Inject a 1 kHz, 50 mV signal from the Audio Gen-
erator.
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 dU
435.000 dU
435.000 dU
435.000 dU
435.000 dU.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “TX Deviation.”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the Deviation Meter
reading is 4.2 kHz (±0.1 kHz).
ˆ Press the [D/MR(MW)] key.