Справочник Пользователя для Vertex Standard FT-1807M

Скачать
Страница из 34
12
CTCSS TX Deviation
ˆ Rotate the DIAL knob to set the alignment param-
eter to “435.000 103
435.000 103
435.000 103
435.000 103
435.000 103.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “CTCSS TX Deviation.”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the Deviation Meter
reading is 0.6 kHz (±0.05 kHz).
ˆ Press the [D/MR(MW)] key.
Alignment
DCS TX Deviation
ˆ Rotate the DIAL knob to set the alignment param-
eter to “43.000 dC
43.000 dC
43.000 dC
43.000 dC
43.000 dC.”
ˆ Press the [D/MR(MW)] key to enable adjustment
of the “DCS TX Deviation.”
ˆ Press the PTT switch to activate the transmitter,
adjust the DIAL knob so that the Deviation Meter
reading is 0.8 kHz (±0.05 kHz).
ˆ Press the [D/MR(MW)] key.
Closing the Alignment mode
Press the [DW(REV)] key to save the new setting and
exit to normal operation.