Справочник Пользователя для Siemens Outboard Motor S120

Скачать
Страница из 301
Maintenance and repairs 
 
11.4 Test and replacement intervals of the cooling medium 
 
1FW6 Built-in torque motors 
170
 
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 
●  Regularly check that the rotary axes can move without hindrance. 
●  Keep the air gap free of chippings and particles. 
●  Regularly check the condition of the motor components. 
●  Check the current consumption in the test cycle defined beforehand. 
 
Ensure that the motor compartment remains free of contamination (e.g. chippings, oil, etc.). 
Depending on the local level of contamination, clean the machine to ensure that it functions 
properly and that heat loss is properly dissipated. 
Check the cables to ensure that they are not damaged and are free of wear and tear. Do not 
use electrical devices with damaged cables. 
Make sure that the cable glands are secure. 
Intervals between maintenance 
Since operating conditions differ greatly, it is not possible to specify intervals between 
maintenance work. 
Indications that maintenance work is required 
●  Dirt in the motor cabinet 
●  Distinctive changes in the behavior of the machine 
●  Unusual sounds emitted by the machine 
●  Problems with positioning accuracy 
●  Higher current consumption 
 
11.4 
Test and replacement intervals of the cooling medium 
Test and replacement intervals of the cooling medium 
The test and replacement intervals for the cooling medium should be agreed with the 
manufacturers of the anti-corrosion agent and the cooling system.