Справочник Пользователя для Sapphire Audio DV425TR

Скачать
Страница из 60
DV425TR DIRECT VENT ROOM HEATER
02/01                                                                                     Page 52                                                                               250-5533
WARNING!    Failure to inspect and maintain the stove may lead to improper combustion and a 
potentially dangerous situation.  The following procedures are recommended to be completed by a 
qualified technician once per year, preferably prior to the burning season.
1. 
Check the pilot flame.  It should engulf approximately 3/8” of the top of the millivolt generator and engulf 
the top of the thermocouple (see illustration  on page 52).
2. 
Shut off gas to the stove by turning the valve control knob to “OFF” and turning off the manual shutoff 
valve.  Allow the stove to cool for 15 minutes.  Remove the door.
3. 
Remove the logset (NOTE: the logs are fragile.  If any log is cracked or deteriorated, replace it when 
reinstalling.  Check the logs for sooting.  A small amount of soot along the bottom of the logs is normal.  
If excessive sooting is found, the fireplace will require adjustment.  Contact your dealer.
4. 
Clean the burner pan (especially in the burner holes and slots) and inspect the following:
a. 
Check for burner pan holes that are cracked, severely warped, plugged or corroded.
b. 
Make sure the burner pan assembly fits flat against the floor of the firebox.  
c. 
Check the firebox and area around the pilot to make sure there is no warping or damage.  If any 
problem is found, discontinue use and contact your dealer for service.
5. 
Reinstall the logset.  Inspect the door glass, if the door glass is damaged, contact your dealer for a 
replacement.  Make sure the gasket along the perimeter of the glass contacts the face of the firebox and 
forms an airtight seal.  If it does not, realign or replace the gasket to ensure an airtight seal. Reinstall 
door. 
6. 
Inspect the area behind the side panels.  Check the gas control valve and all of the gas lines.  If any 
damage is found, discontinue use and contact your dealer for service.
7. 
Remove any debris or vegetation near the vent termination, outside the house ensuring that the flow 
of combustion and ventilation air is not obstructed.  Contact your dealer if any sooting or deterioration 
is found near the vent termination.
8. 
Turn on gas and follow Lighting Instructions. The flames should be orange/yellow and not touch the 
top of the firebox.  If the pilot or main burners do not burn correctly, contact your dealer for service.  
Monitor the blower operation.
YEARLY MAINTENANCE PROCEDURES