DV425TR DIRECT VENT ROOM HEATER
02/01                                                                                     Page 54                                                                               250-5533
TROUBLE SHOOTING
Problem: 
 
Possible Cause: 
 
 
      Solutions:
Pilot will not light. 
Air in Gas Lines.   
Bleed air from Gas Line.
 
 
 
Wrong Inlet Pressure. 
Check Gas Line pressure (7” Nat., 11” L.P.). 
 
 
 
Defective Spark   
Replace Electrode if the Insulator is cracked or the Tip is 
 
 
 
 
Electrode. 
corroded.  Verify that the Spark Gap between the Pilot and 
 
 
 
 
 
 
the Electrodes correct.
 
 
 
Defective Piezo Wire. 
Replace Piezo Wire if Insulation is damaged, broken, or
 
 
 
 
 
 
corroded.
 
 
 
Safety Interlock   
Allow Thermocouple to cool until the mV drops below the
 
 
 
Function engaged. 
hold - in requirements of the Safety Magnet (30 seconds or
 
 
 
 
 
 
less).  Relight Pilot.
Pilot will not hold
Wrong Inlet Pressure. 
Check Gas Line pressure (7” Nat., 11” L.P.). 
 
 
 
Pilot Adjustment Screw 
After the Pilot has been lit for approximately [3] min., and only
 
 
 
not adjusted properly. 
the Thermo-generator wires connected to the Main Operator 
 
 
 
 
 
 
Head, measure the voltage across TPTH and TP.  This Open
 
 
 
 
 
 
Circuit voltage should be between 500mV and 750mV.  Tune
 
 
 
 
 
 
the Pilot Adjustment Screw until the  mV  reading falls within
 
 
 
 
 
 
these parameters.  Counter-clockwise increases the mV 
 
 
 
 
 
 
reading, Clockwise decreases it.  Turn with a Wrench.  
 
 
 
Thermocouple or   
With the Thermocouple and Thermo-generator Tips cool, 
 
 
 
Thermo-generator has 
clean the upper 3/8” with a very fine Emery cloth.
 
 
 
Film build-up on Tip. 
 
 
 
Electrical Resistance 
Using a very fine Emery cloth, clean the Thermo-generator 
 
 
 
too high.  
 
and Thermocouple connections at the Valve.  Tighten    
 
 
 
 
 
 
Thermocouple into Valve, hand tight, adding a 1/4 turn
 
 
 
 
 
 
with a wrench.
 
 
 
Defective  
 
Verify that the  Thermocouple  is not kinked or damaged.  
 
 
 
Thermocouple.   
Check Open-Circuit voltage of Thermocouple.  Voltage should 
 
 
 
(mV Plus System) 
be between 18mv and 28mv.  If voltage is less than 14mv,
 
 
 
 
 
 
replace the Thermocouple.
 
 
 
Defective Thermo- 
After the Pilot has been lit for approximately [3]  min.,and only
 
 
 
generator. 
 
the Thermo-generator wires connected to the Main Operator H
 
 
 
(millivolt System)   
Head, measure the voltage across TPTH and TP.  This Open
 
 
 
 
 
 
Circuit  voltage should be between 500mV and 750mV.  Tune
 
 
 
 
 
 
the Pilot Adjustment Screw until the mV reading falls within
 
 
 
 
 
 
these parameters.  Counter-Clockwise increases mV reading, 
 
 
 
 
 
 
Clockwise decreases it.
 
 
 
Defective Safety Magnet  Verify operation of Safety Magnet in the following manner:
 
 
 
(mV Plus Systems). 
(A) Depress and hold the Pilot Button.
 
 
 
 
 
 
(B) Verify Open-Circuit Thermocouple voltage as described
 
 
 
 
 
 
      in previous Step.
 
 
 
 
 
 
(C) Reconnect Thermocouple to the Valve.