Справочник Пользователя для National Instruments Welding System 321645c-01

Скачать
Страница из 554
Chapter 2
Function Reference — DIG_DB_Config
NI-DAQ FRM for PC Compatibles
2-158
©
 National Instruments Corporation
DIG_DB_Config
Format
status = DIG_DB_Config (deviceNumber, group, dbMode, oldDataStop, partialTransfer)
Purpose
Enables or disables double-buffered digital transfer operations and sets the double-buffered 
options.
Parameters
Input
Parameter Discussion
group is the group to be configured.
Range:
1 or 2.
dbMode indicates whether to enable or disable the double-buffered mode of digital transfer.
0:
Disable double buffering (default).
1:
Enable double buffering.
oldDataStop is a flag whose value enables or disables the mechanism whereby the function 
stops the digital block output when NI-DAQ is about to output old data a second time. For 
digital block input, oldDataStop enables or disables the mechanism whereby the function 
stops the input operation before NI-DAQ overwrites unretrieved data.
0:
Allow regeneration of data.
1:
Disallow regeneration of data.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
group
i16
group
dbMode
i16
enable or disable double-buffered mode
oldDataStop
i16
enable or disable regeneration of old data
partialTransfer
i16
enable or disable transfer of final partial half 
buffer