Timed Pulse Output
The NI 1450 is capable of timed pulse output on six different digital 
outputs, which provides precise control over time-critical signals, such as 
camera exposure. This section describes the various uses for the timed 
pulse output and the parameters you can set to control these outputs.
Uses for timed pulse output include controlling camera reset and exposure, 
controlling strobe lighting, operating plungers on an assembly line, and 
communicating with PLCs. You can configure the start of the pulse output 
generation to occur from software or from a rising or falling edge of a 
trigger input. 
In addition to controlling the timing of pulse output, you can also configure 
the polarity of the output signal, resulting in a high-true or low-true signal. 
Based on the polarity setting, the output signal asserts after the appropriate 
delay time and de-asserts after the configured pulse width. You can set the 
delay time in microseconds or in quadrature encoder counts from the start 
signal—either a hardware trigger or a software command. Width is always 
configured in microseconds.
Initiating a Timed Pulse
Each timed pulse generator has a trigger input that specifies whether to wait 
on a particular trigger input to generate the pulse or to immediately 
generate the pulse when software sets the mode to Start.
When the pulse generator is configured for a particular trigger input, after 
generating a pulse, it waits for another trigger before generating another 
pulse. When the pulse generator is configured to immediately generate the 
pulse on a software start, after generating a pulse, it immediately generates 
another pulse.
If the trigger input is set to immediate, the pulse generation occurs as soon 
as the pulse mode is set to start. If the trigger input is set to one of the 
hardware trigger inputs, the timed pulse output waits for an assertion edge 
on the appropriate trigger input. The assertion edge is configurable based 
on the trigger polarity parameter. It then generates one pulse and rearms to 
wait for the next trigger. In either case, the pulse output generation stops 