Справочник Пользователя для National Instruments NI 1450 Series

Скачать
Страница из 83
Chapter 4
Digital I/O Functionality
© National Instruments Corporation
4-5
Figure 4-1 shows an output pulse when a trigger is selected.
Figure 4-1.  Output Pulse When Trigger Is Selected
Pulse Modes
Each pulse generator has a Start and a Stop mode. Configure the pulse 
generator when in Stop mode and then set it to Start mode.
Pulse Delay
Pulse delay is the amount of time between a trigger and the first (assertion) 
edge of an output pulse. The pulse delay is configurable in units of 
microseconds or quadrature encoder counts. If configured for 
microseconds, available values are between 10 
µs and 4,294,967,295 µs, 
which is 4,294 seconds, or approximately 71 minutes. If the delay is 
configured for quadrature encoder counts, the range of choices is 0 counts 
to 4,294,967,295 counts.
Pulse Width
Pulse width is the amount of time between the first (assertion) edge of a 
pulse and the second (deassertion) edge. Pulse width is configurable only 
in microseconds from 10 
µs to 4,294,967,295 µs.
Trigger Polarity
Each pulse generator can be individually configured for rising or falling 
edge triggering. Even if multiple pulse generators are using the same 
trigger, each can have different polarities.
Figure 4-2 shows the output of a pulse generator configured to look for a 
rising edge trigger and output a high pulse with a microsecond width and 
delay.
Output 
Pulse
Trigger
Input