Справочник Пользователя для Kärcher 600 CD

Скачать
Страница из 93
13
WTC 600 LP / MP
DESCRIPTION
Service Handbook 08.2004
2.3
Description of the System
2.3.1
Modular Design
The installation is a drinking water conditioning system. Its core application is the
emineralization of brackish water with a salt content up to 2000 ppm (WTC 600 LP), respectively
up to 5000 ppm (WTC 600 MP).
The design of the system is modular, and can be adapted accordingly to the local conditions
depending on the application conditions as well as the composition of the untreated water:
- Media filter and flocculation – module 1
- Activated carbon filter – module 2
- Reverse osmosis system – module 4
- Pressure-increase pump – module 5
- Metering stations
The RO system is designed for stationary use.
2.3.1.1
Pre-chlorination Module
The WTC 600 CD metering station, consisting
of metering container (3/1) and pump (3/2), is
connected to the sand filter module for pre-
chlorination if required.
2.3.1.2
Flocculation Module
The WTC 600 CD metering station (see figure 3) with injection adapter is connected to the sand
filter module for pre-flocculation if required.
The exact requirement of flocculation agent is to be determined when starting operation (see
Section 3.2.5).
Figure 3
WTC 600 CD
1
2