DESCRIPTION
Service Handbook 08.2004
2.3.1.7
Pressure-increase Pump
If required, the WTC 600 PI pressure-increase
pump (6/1) is connected between untreated
water supply and RO system. It is used for
pressure increase of the untreated water.
A pressure-increase pump should
be used for a water pressure (flow
pressure)  
 2 bar.
Observe mechanical protection as
well as protection of the
connection cable against water!
2.3.2
Safety Installations
Emergency Stop
The emergency stop switch (7/4) (main switch) is located on the side of the switch box.
RC Protective Switch
RC protective switch (external): i 
 30 mA
Circuit Breaker
Automatic circuit breaker (7/3) 10 A for power limitation of the power outlets, etc
Motor Protection Switch
The motor protection switch (7/2) is factory-set depending on the power consumption of the RO
pump (compare circuit diagram (7/1)) and must be checked:
WTC 600
Nominal output
Actual power
Motor protection
RO pump
consumption
switch setting
LP 400 V
2.2 kW
1.5 kW
4 A
MP 400 V
2.2 kW
2.2 kW
5.1 A
LP 230V
2.2 kW
1.5 kW
10 A
MP 230 V
2.2 kW
2.2 kW
14 A
Table 2
Setting of motor protection switch
Figure 6
WTC 600 PI
1
NOTE
CAUTION