Clearances to NFPA 211 Protected Surfaces 
 
You can reduce the clearances to combustible surfaces by 
using any National Fire Protection Agency (NFPA) 
approved wall protection system.  Please refer to NFPA 
211 for specifications and complete details.  You can 
obtain this information directly from NFPA. 
 
Clearances to combustible surfaces can be reduced by 
using any NFPA approved wall protection system. 
 
REFER TO NFPA 211 FOR SPECIFIC AND 
COMPLETE DETAILS: 
 
National Fire Protection Agency 
Battery March Park 
Quincy, MA 02269 
1-800-344-3555 
1-617-770-3000 
 
CLEARANCE TO COMBUSTIBLES 
COMBUSTIBLE MANTLE
SI
DE
 W
AL
L
SIDE 
TRIM
 
Figure 5 Clearance to Combustibles 
A.  side wall    
 
 
= 13” 
B.  mantle and top trim 
 
= 34”  
B.  mantle/ with mantle shield kit 
= 22”  
C. 
 
trim 
    = 
3” 
REMOVING THE BAFFLE    
In order to connect the flue to the Morgan, you will need 
to remove and install the baffle. Use Figure 6 to refer to 
while removing and replacing the baffle. 
 
BE CAREFUL WHEN HANDLING THE BAFFLE, 
NOT TO PUNCTURE THE CERAMIC BOARD  
 
To remove the baffle: 
1.  Lift the front of the baffle. This relieves the 
weight from, and unlocks the shelf tabs. 
2.  Pull forward to free the baffle. 
3.  The baffle should now be free to drop down and 
pull out of the front door, or rest on the floor of 
the insert 
Once the baffle is removed from the unit, you will have 
direct access to the flue collar, and all venting connections 
 
To install the baffle, reverse the order of removing the 
baffle.
 
Shelf tabs
Baffle 
sleeves
 
Figure 6 Baffle Placement 
 
V
ENTING 
C
OMPONENTS AND 
C
ONFIGURATION
 
 
It is very important to follow minimum clearances for 
chimney connectors to combustibles such as walls and 
ceilings when installing the stove near non-
combustible surfaces 
 
•  Single wall connector is 24 MSG or 25 MSG blued 
steel stovepipe. 
 
•  Double wall connector (close clearance pipe) which 
must be used with a listed factory-built “Type HT" 
chimney also may be used with a masonry chimney to 
reduce clearances, is available from several 
manufacturers, your dealer can help you choose.  
Some air insulated connector pipe models available 
are Simpson Dura Vent DVL and Metalbestos DS. 
Security, GSW and Ameritec also have acceptable 
close clearance connector pipe. 
 
•  Chimney connector shall not pass through floor or 
ceiling, nor any attic or roof space, closet or similar 
concealed space.  Where passage through a wall or 
partition of combustible construction is desired, the 
installation shall conform to NFPA 211 or CAN/CSA 
- B365. 