•  It is very important to follow minimum clearances for 
chimney connectors to combustibles such as walls and 
ceilings when installing the stove near non-
combustible surfaces.  Typical chimney connector 
clearances are outlined below.  The single wall 
clearances are generic; the Double wall clearances are 
for Simpson Dura Vent DVL, CHECK THE 
SPECIFICATIONS FROM THE 
MANUFACTURER OF YOUR CONNECTOR.
 
 
I
NSTALLING A 
V
ENTING 
S
YSTEM
 
 
DO NOT CONNECT THIS UNIT TO ANY AIR 
DISTRIBUTION DUCT OR SYSTEM 
 
Secure all joints, including attaching the stovepipe to the 
Fireplace Insert's flue collar, with three sheet metal 
screws.  Install #10 x 1/2" (3 mm x 13 mm) sheet metal 
screws into the holes pre-drilled in the flue collar.  
Leaving off the screws can cause joints to separate from 
the vibration that results from a creosote chimney fire.   
 
Long runs of stovepipe to increase heat dispersal are not 
recommended
.  Using longer lengths of stovepipe or more 
connecting elbows than necessary increase the chances of 
draft resistance and the accumulation of creosote buildup. 
 
Remember, the NFPA has recommended, minimum 
clearances for chimney connectors to combustibles such 
as walls and ceilings.  Once the Fireplace Insert is 
installed at safe distances from these combustible 
surfaces, it is important to maintain these connector 
clearances for the remainder of the installation.   
 
C
ONNECTING 
Y
OUR 
W
OOD 
F
IREPLACE 
I
NSERT
 
 
You can install your Morgan to a prefabricated metal 
chimney or a masonry chimney. See figure 7 to aid in 
connections. 
 
C
ONNECTING TO A 
P
REFABRICATED 
M
ETAL 
C
HIMNEY 
(A 
FULL FLUE LINER IS REQUIRED IN CANADA
 
IT IS STRONGLY RECOMMENDED THAT THIS 
FIREPACE INSERT IS INSTALLED WITH A 
CONTINUOUS CHIMNEY LINER WITH A 
MINIMUM DIAMETER OF 6” EXTENDING FROM 
THE FIREPLACE INSERT TO THE TOP OF THE 
CHIMNEY. THE CHIMNEY LINER MUST 
CONFORM TO THE CLASS 3 REQUIREMENTS OF 
CHIMNEY LINER STANDARDS CAN/ULC-S635 OR 
CAN/ULC- S640 
 
You can install the Morgan in a masonry or zero 
clearance fireplace. Before installing the stove in a 
factory-built fireplace, the fireplace must have the 
following characteristics: 
1. 
Listed per UL 127 or ULC S610. 
2. 
Include a full height listed chimney liner meeting 
type HT requirements (2100° Fahrenheit) per UL 1777 
(United States) or ULC S635 (Canada) standards, or with 
a direct flue connector into the first chimney liner section 
3. 
The means to prevent room air passage to the 
chimney cavity of the fireplace. 
4. 
Does not disturb the airflow in or within the 
fireplace when installed (louvers, or cooling air inlet or 
outlet ports must not be blocked). 
5. 
Not be altered in any way, except for the 
following: 
a. 
External trim pieces which do not affect 
the operation of the fireplace can be removed, providing 
they are stored on or within the fireplace for re-assembly 
if the insert is removed. 
b. 
The chimney damper can be removed to 
install the chimney liner. 
6. 
Must not have blocked circulating chambers (if 
available). 
7. 
The means for removing the insert to clean the 
chimney flue. 
8.   Have a permanent metal warning label (provided  with 
the Morgan—see illustration to the below)  attached to the 
fireplace by riveting it to the outside wall, stating that the 
fireplace must be restored to its original condition for safe 
use without the insert.  
Remember, you must adhere to all previously described 
floor protection requirements when installing into a zero 
clearance fireplace. 
 
▌  WARNING: 
DO NOT CONNECT THE FIREPLACE INSERT 
TO A CHIMNEY FLUE SERVING ANOTHER 
APPLIANCE. 
 
Make sure the size of the chimney’s flue is appropriate for 
the Morgan.  The Morgan requires a 6" (152 mm) inside 
diameter flue for new installations.  A 6” diameter flue 
provides adequate draft and performance.  You can use an 
8" (203 mm) diameter existing flue with a reducer.  An 
oversized flue contributes to creosote accumulation.  (In 
this case, bigger is NOT better.) 
 
When purchasing a prefabricated chimney to install with 
your Fireplace Insert, be sure to also purchase from the 
same manufacturer the wall pass-through (or ceiling 
support package), "T" section package, fire-stops (when 
HearthStone Quality Home Heating Products, Inc. ®                                                                                                                                                                       Morgan Model 8470            
11