Справочник Пользователя для Listen Technologies PS 6000

Скачать
Страница из 14
Danish Interpretation Systems 
 
User Manual 
 
Manual 01 18 04450 
 
10
Max. number of units to be connected 
The following tables show the maximum number of 
units,  which  can  be  connected  to  the  two  outputs 
(A1 or A2) on a CU 6005 Central Unit in total or to 
each  of  the  four  outputs  (A1,  A2,  B1  or  B2)  on  a 
CU  6010  Central  Unit  or  to  each  output  on  an  EX 
6010 Extension Unit or to the output of a PS 6000 
Power Supply. 
CM/DM 60x0P Chairman/Delegate Units  
Length of Feeding Cable 
Type CAT5 AWG24  
Length of  inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of CM/DM 
60x0   pr output 
10 m 
1 m 
51 m 
42 
30 m 
1 m 
67 m 
38 
50 m 
1 m 
83 m 
34 
100 m 
1 m 
123 m 
24 
150 m 
1 m 
165 m 
16 
10 m 
2 m 
88 m 
40 
30 m 
2 m 
98 m 
35 
50 m 
2 m 
108 m 
30 
100 m 
2 m 
142 m 
22 
150 m 
2 m 
180 m 
16 
CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box 
This  configuration  shows  two  CM/DM  60x0 
Delegate/Chairman Units connected to one JB 6002 
Junction  Box  with  3m  cables  between  each  JB 
6002.  Maximum  5  m  cable  from  JB  6002  to 
CM/DM 60x0 and max. one CM/DM 60x0 on each 
output of JB 6002. 
Length of Feeding Cable, 
Type CAT5 AWG24 
Length of  Cable between each     
JB 6002, Type CAT5 AWG24 
Total cable 
length 
Number of  
JB 6002 
Max. number of  
DM 60x0 
10 m 
3 m 
61 m 
18 
36 
30 m 
3 m 
75 m 
16 
32 
50 m 
3 m 
89 m 
14 
28 
100 m 
3 m 
127 m 
10 
20 
150 m 
3 m 
168 m 
14