System Setup 
General guidelines 
Connect the PS 6000 to the various DCS 6000 units 
using Cat5 or Cat5e FTP or STP screened cables. 
Please observe the following guidelines: 
 
Maximum cable length in one chain is 200 
without 
repeater. 
This 
includes 
interconnection  cables  between  the  units. 
The  max.  usable  cable  length  depends  on 
the  units  connected  and  length  of  feeding 
cables etc. 
 
Maximum  cable  length  in  one  chain  when 
using repeaters is 650 m. 
 
Although the output on the PS 6000 have a 
125W  supply,  this  125W  power  is  not  all 
usable  with  long  cables,  as  there  will  be  a 
voltage  drop  in  the  feeding  cable  from  the 
PS  6000  to  the  units  connected.  If  the 
feeding  cables  are  short  and  the  cables 
between the units are short, more units can 
be  connected  than  if  the  feeding  cable  is 
long and/or the cables are long between the 
units. Please consult the next section (Max. 
Number of units to be connected) 
 
If  the  last  unit  in  one  chain  is  a  CS  6032 
Channel  Selector,  this  unit  has  to  be 
terminated  with  an  external  termination,  as 
the  CS  6032  does  not  have  an  internal 
termination. 
It  is  desirable that  the  square  of the  feeding  cables 
especially, but also the interconnection cables are as 
big as possible to minimize the voltage drop in the 
cables. Cat 5/Cat5E cables are delivered in various 
gauges: 
The following table is showing the Diameter/square 
for various AWG types 
 
Type 
Diameter 
Square 
AWG22 
0.64 mm 
0.32 mm2 
AWG23/1 
0.57 mm 
0.25 mm2 
AWG24 
0.53 mm 
0.22 mm2 
AWG26 
0.42 mm 
0.14 mm2