Heat & Glo  •  6000TR-OAK, 6000TR-OAK-IPI  •  383-901  Rev. K  •   5/06
26
V
= VENT  TERMINAL
X
= AIR SUPPLY INLET
= AREA WHERE TERMINAL IS NOT PERMITTED
     Figure 29.  Minimum Clearances for Terminations
A
= 12" ....................... clearances above grade, veran-
da, porch, deck or balcony
B
= 12" ....................... clearances  to  window  or  door
that may be opened, or to per-
manently  closed  window.
D*
= 18" ....................... vertical clearance to unventilat-
ed soffit or to ventilated soffit lo-
cated above the terminal
 *30” ...................... for  vinyl  clad  soffits  and  below
electrical  service
F
=  9" ........................ clearance to outside corner
G
= 6" ......................... clearance to inside corner
H
= 3 ft. (Canada) ...... not  to  be  installed  above  a  gas
meter/regulator  assembly  within
3 feet (90cm) horizontally from the
center-line of the regulator
I
= 3 ft. (U.S.A.)
6 ft. (Canada) ...... clearance  to  gas  service  regu-
lator vent outlet
J
= 9" (U.S.A.)
12"  (Canada) ........ clearance to non-mechanical air
supply  inlet  to  building  or  the
combustion air inlet to any other
appliance
K
= 3 ft. (U.S.A.)
6 ft. (Canada) ......... clearance  to  a  mechanical
air supply inlet
L** = 7 ft. ......................... clearance  above  paved
sidewalk or a paved driveway
located on 
public property
M*** = 18" ......................... clearance  under  veranda,
porch, deck, balcony or over-
hang
42” ......................... vinyl
N
= 6” ........................... non-vinyl  sidewalls
12” ......................... vinyl  sidewalls
P
= 8 ft.
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE
INSTALLED.
  ** a  vent  shall  not  terminate  directly  above  a  sidewalk  or  paved
driveway  which  is  located  between  two  single  family  dwellings
and  serves  both  dwellings.
 *** only permitted if veranda, porch, deck or balcony is fully open on
a minimum of 2 sides beneath the floor, or meets Note 2.
NOTE 1:  On  private  property  where  termination  is  less  than  7  feet
above a sidewalk, driveway, deck, porch, veranda or balcony, use of
a listed cap shield is suggested.
NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specified for
vinyl or non-vinyl siding and soffits. 
1. There must be 3 feet minimum
between termination caps. 
2.  All mechanical air intakes within 10 feet
of a termination cap must be a minimum of 3 feet below the termination
cap.
3. All gravity air intakes within 3 feet of a termination cap must be
a minimum of 1 foot below the termination cap.
M
N
P
R
Q
(See Note 1)
(See Note 1)
(See Note 2)
S =  6" .......................... clearance from sides of elec-
trical service
T = 12" ......................... clearance  above  electrical
service
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
______________________________________________________________________
Q
MIN
     R
MAX
  1 cap
  3 feet
   2 x Q 
ACTUAL
  2 caps
  6 feet
   1 x Q 
ACTUAL
  3 caps
  9 feet
2/3 x Q 
ACTUAL
  4 caps
12 feet
1/2 x Q 
ACTUAL
Q
MIN
 = # termination caps x 3        R
MAX
 = (2 / # termination caps) x Q
ACTUAL
(See Note 5)
(See Note 5)
Electrical
Service
V
S
V
S
V
T
D*
V
NOTE 3:  Local  codes  or  regulations  may  require  different
clearances.
NOTE 4: Termination caps may be hot. Consider their proximity to
doors  or  other  traffic  areas.
NOTE 5: Location of the vent termination must not interfere with
access  to  the  electrical  service.
WARNING: In the U.S: Vent system termination is NOT permitted
in  screened  porches. You  must  follow  side  wall,  overhang  and
ground clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches.  Vent  system  termination  is  permitted  in  porch  areas
with  two  or  more  sides  open.  You  must  follow  all  side  walls,
overhang and ground clearances as stated in the instructions.
Heat  &  Glo  assumes  no  responsibility  for  the  improper  perfor-
mance of the fireplace when the venting system does not meet
these  requirements.