Справочник Пользователя для Cumberland Stove Works OMMF3500

Скачать
Страница из 38
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 
800-345-6007
CumberlandStoveWorks.com
6”
6”
6”
3”
PARLOR STOVE FLOOR PAD CLEARANCES
INSTALLATION
It is recommended the stove be installed and serviced by 
authorized professionals who are certified by the National 
Fireplace Institute (NFI) as NFI Pellet Specialists. 
Proper installation of this stove is necessary for safe and 
efficient operation. Installing this product improperly may 
result  in  a  house  fire  and  personal  injury.  All  applicable 
building  codes  for  your  location  must  be  followed.  In 
areas  where  building  codes  require  additional  steps  to 
the installation of this product not included in this manual, 
the  building  codes  will  take  precedent  and  must  be 
followed.  Contact your local building inspector to obtain 
any  necessary  permits  or  inspection  guidelines  before 
installing the product.
STOVE PLACEMENT
Sketch out a plan for installing the stove including dimensions 
before  permanent  placement.  When  determining  the 
location for the stove, wall stud location is critical. You may 
need to adjust the location of the stove to avoid trying to 
vent through a wall stud. Before placing the parlor stove, 
connect  the  vent  and  allow  for  minimum  clearance  to 
combustible walls. 
FLOOR PROTECTION REqUIREMENTS
The stove must be installed on a noncombustible floor, with 
proper floor protection, or on a masonry hearth. The hearth 
or noncombustible floor protector must extend a minimum 
of  6”  in  front,  6”  from  each  side,  and  3”  from  back. The 
minimum floor protector material is 24 gauge sheet metal. 
The floor protector must extend 2” beyond each side and 
rear of the T-vent.
WARNING
READ THIS  ENTIRE  MANUAL  BEFORE YOU  INSTALL
AND  USE THIS  STOVE.  FAILURE TO  FOLLOW THE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
DO  NOT  CONNECT THIS  UNIT TO  A  CHIMNEY  FLUE
SERVING ANOTHER APPLIANCE.
CHILDREN  AND  ADULTS  SHOULD  BE  ALERTED TO
THE  HAZARDS  OF  HIGH  SURFACE TEMPERATURES
AND SHOULD STAY AWAY TO AVOID BUMPS TO SkIN
AND/OR CLOTHING.
YOUNG  CHILDREN  SHOULD  BE  CAREFULLY
SUPERVISED WHEN THEY  ARE  IN THE  SAME  ROOM
AS THE STOVE.
CLOTHING  AND  OTHER  FLAMMABLE  MATERIALS
SHOULD NOT BE PLACED ON OR NEAR THIS UNIT.
CAUTION
THIS  STOVE  SHOULD  NOT  BE  USED  AS THE  ONLY
SOURCE OF HEAT IN THE HOUSE. POWER OUTAGES
AND  PERIODIC  MAINTENANCE WILL  RESULT  IN  A
TOTAL LOSS OF HEAT.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS  AND  INSTALLATION  INSPECTION
REqUIREMENTS IN YOUR AREA.
CONTACT YOUR  LOCAL  AUTHORITY  (SUCH  AS
MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT,
FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE
NEED FOR A PERMIT.
kEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS,
LEAVES, ETC.) AT LEAST 3 FEET AWAY FROM THE FLUE
OUTLET ON THE OUTSIDE OF THE BUILDING.
INSTALLATION AND REPAIR OF THIS PARLOR STOVE
SHOULD BE DONE BY A qUALIFIED SERVICE PERSON.
THE  APPLIANCE  SHOULD  BE  INSPECTED  BEFORE
USE  AND  AT  LEAST  ANNUALLY  BY  A  qUALIFIED
SERVICE PERSON. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS, AND CIRCULATING AIR
PASSAGEWAYS OF THE STOVE BE kEPT CLEAN.