Справочник Пользователя для Cumberland Stove Works OMMF3500

Скачать
Страница из 38
INSTALLATION AND OPERATION MANUAL
MF3500G, MF3500S, MF3500B Models
Page 3
800-345-6007
CumberlandStoveWorks.com
OUTSIDE AIR CONNECTION
Connection to outside the house is 
REqUIRED for mobile 
home installations. Direct air access must be provided, use 
a Fresh Air Kit (not included). 
Only  noncombustible  pipe  2”  (or  greater)  in  diameter  is 
approved  to  use  for  outside  air  connections  (straight  or 
flexible). 
PVC pipe is NOT approved and should NEVER
be used. 
If  the  air  inlet  is  connected  to  the  outside,  it  MUST  be 
terminated with a vertical 90º bend (down) or with a wind 
hood. Failure to do so could result in a burn back during high 
winds blowing directly up the air inlet during a simultaneous 
power failure. 
Blockage, excessive length, or extra bends in the air intake 
pipe will starve the stove of combustion air. A 90º bend is 
equivalent  in  restriction  to  approximately  30”  of  straight 
inlet pipe.
MOBILE HOME
Installation in a mobile home should be in accordance with 
the manufactured home and safety standard. Department 
of  Housing  and  Urban  Development  (HUD)  CITE: 
24CFR3280.707 stating this stove must be vented to the 
outside. In addition to the standard installation instructions, 
the following requirements are mandatory for installation 
in a mobile home: 
1.  Stove must be bolted to the floor. Stove will have four 
tie-down straps that bolt to the feet and the floor.
2.  Stove must have an outside air source. 
3.  Stove must be electrically grounded to the steel chassis 
of the mobile home. 
4.  All vertical chimney vents must have wall supports. 
5.  All exhaust systems must have a spark arrestor.
WARNING
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM
.
DO NOT INSTALL IN A SLEEPING ROOM.
B
C
B
C
Mobile Home Anchor & Leg Assembly
CAUTION
THE  OPERATION  OF  EXHAUST  FANS  SUCH  AS
BATHROOM FANS, ATTIC FANS, ETC. MIGHT STARVE
THE  PARLOR  STOVE  OF  COMBUSTIBLE  AIR
CREATING  A  NEGATIVE  PRESSURE  IN THE  ROOM.
PROVIDE  ADEqUATE VENTILATION  IN THE  ROOM
ACCOMPANYING THE  PARLOR  STOVE.  IF  NOT, THE
PRESSURE SWITCH MAY SHUT OFF OPERATION OF
THE PARLOR STOVE.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED
HOME  FLOOR, WALL,  AND  CEILING/ROOF  MUST  BE
MAINTAINED.
Tie-down Straps
Bolt