Справочник Пользователя для Advantech Barcode Reader RS-485
6-92
ADAM-5000
Command Set
$aaSiCjArrff
$aaSiCjArrff
? delimiter character indicating the command was
invalid.
invalid.
aa (range 00-FF) represents the 2-character hexadecimal
address of an ADAM-5000 system.
address of an ADAM-5000 system.
(cr) is the terminating character, carriage return (0Dh)
Example
command: $35S3C0A3110(cr)
response: !35(cr)
The analog output channel 0 in slot 3 of the ADAM-
5000 system at address 35h is configured to an output
range 4 to 20mA, engineering units data format, and a
slew rate of 1.0mA/sec.
5000 system at address 35h is configured to an output
range 4 to 20mA, engineering units data format, and a
slew rate of 1.0mA/sec.
The response indicates that the command has been
received.
received.
Note:
An analog output module requires a maximum of 20
milliseconds to perform auto calibration and ranging
after it is reconfigured. During this time span, the
module cannot be address to perform any other
actions.
milliseconds to perform auto calibration and ranging
after it is reconfigured. During this time span, the
module cannot be address to perform any other
actions.
Figure 6-4 Data format of 8-bit parameters
5024 Analog Output