DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
9
<cr>, then $CONFIG followed by <cr>. This will allow access to the
configuration menu for that module. Once configuration is complete, type
X for “Exit” followed by <cr>. To access the main menu, type the
attention character five times.
NOTE: You must exit main menu to send ASCII character string commands.
NOTE:  While operating using the ASCII Character String method, consider placing the DS-
Series in binary mode.
Binary Mode
If binary data containing the port select code is sent to a module, the DS-
Series may interpret the data as a command to change ports.  Binary mode
prevents such an occurrence by placing the DS-Series in a mode which
does not look at the data. This provides a reliable binary data transmission.
However, before a connection can be made to another port, the binary
mode must be terminated.
Place the port in binary mode by sending the port select code, a capital B,
and a carriage return ($BTB).  For example, if using the default Port
Select Code ($BT), place Module 2, Port 1 in binary mode by typing
$BT2,1<cr>$BTB<cr>.
Terminate Binary                 From   the   terminal   emulation   software,   send   a    BREAK   condition
Mode
command to terminate binary mode.  You may have to consult the
software users’ manual for the specific BREAK condition command for
the emulation software you are using. For example, the BREAK condition
command for PROCOMM PLUS is “Alt B.”
NOTE:  The break length for emulation software is programmed within that software. The break
length for a TELNET session is programmed within the BayTech firmware. This procedure is
discussed on page 20.
Data Switch Series - F.1.00
Bay Technical Associates
Unit ID: BAYTECH DS72
Port Select Code: $BT
Attention Character: ;
Device A        (2,1)...........1
Device B        (2,2)...........2
Device C        (2,3)...........3
Device D        (2,4)...........4
DS-RPC          (3,1)...........5
Configure.......................C
Status..........................S
I/O Modules Reset...............RM
Unit Reset......................RU
Exit............................X
Logout..........................T
Enter Request :