DS72 HOST MODULE OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
11
Login Setup :
Header is.......................Enabled
Password is.....................Disabled
Menu is.........................Enabled
Auto Connect Port is............Module 3,Port 1
Auto Connect is.................Disabled
SERIAL  PORT                    DS72   modules    perform   data   rate   conversions   for     devices   using
CONFIGURATION
different serial configurations.See  Appendix  A,  “SPECIFICATIONS”  for
available serial parameters.  Default Serial Port Configurations are
9600 bps, 8 data bits, 1 stop bit, no parity, Xon/Xoff disabled, RTS
high, and DTR low. 
From the configuration menu, select #2, “Serial Port
Configuration”, followed by <cr>. The DS72 unit displays the following
table:
Module  1 Serial Port Configuration :
Port
Device
Name
Baud
Rate
Word
Size
Stop
Bits
Parity
Xon/
Xmit
Xoff/
Recv
Line
DTR
Drive
RTS
1
EIA-232
9600
8
1
None
Off
Off
High
High
Save.......1  Parity............5
Baud Rate..2  Xon/Xoff..........6
Word Size..3  RTS Line Driver...7
Stop bits..4  DTR Line Driver...8
Enter Request :
Select the corresponding number to configure baud rate, word size, stop
bits, parity...
NOTE:  DTR is unchangeable when configuring the serial port.
For example, to change the baud rate to 115.2K, select #2, “Set Baud Rate,”
followed by <cr>.
The DS71 displays the following list of available baud rates:
1  for   300
2  for   600
3  for  1200
4  for  2400
5  for  4800
6  for  9600
7  for 19200
8  for 38400
9  for 57.6K
A  for 76.8K
B  for 115.2K
Enter Request :
Type "B" for 115.2K baud rate.  The DS72 responds with the new
configuration status: