Инструкции По Установке для White Rodgers 25M01A-100 25M Gas Dryer Valves

Скачать
Страница из 4
REGULATOR
ADJUSTMENT
TOWER
REGULATOR COVER
SCREW
PLASTIC ADJUST SCREW
REGULATOR SPRING
HOSE BARB 
INSTALLED
Figure 5
Figure 6
1.  Unplug power cord to the appliance.
2.  Slide dryer away from wall.
3.  Close manual shut-off valve for dryer, if none present, shut off gas supply line where it enters the building.
  A.  This appliance does not have a pilot. It is equipped with an 
ignition device which automatically lights the burner. Do 
not 
try to light the burner by hand.
 B. 
BEFORE OPERATING smell all around the appliance area 
for gas. Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.
FOR YOUR  SAFETY 
“WHAT TO DO IF YOU SMELL GAS”
 
•  Do not try to light any appliance.
 
•  Do not touch any electrical switch; do not use any
phone in your building.
•  Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
•  If you cannot reach your gas supplier, call the
fire department.
  C.  Do not use this appliance if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and to replace any part of 
the control system and any gas control which has 
been under water.
WARNING
!
If  you  do  not  follow  these  instructions  exactly,  a  fire  or  explosion 
may result causing property damage, personal injury or loss of life.
White-Rodgers is a business 
of Emerson Electric Co.
The Emerson logo is a  
trademark and service mark 
of Emerson Electric Co.
www.white-rodgers.com
www.emersonclimate.com
1.  Unplug dryer power cord.
2.  Attach a hose and manometer to the hose barb in the tap 
of the valve (see figure 5).
3.  Turn on system power and energize valve.
4.  Remove regulator cover screw and turn regulator adjust 
screw 
clockwise (
to increase pressure, or coun-
terclockwise (
to decrease pressure (see figure 
6). Always adjust regulator to provide the correct pressure 
according to the original equipment manufacturer’s speci-
fications listed on the appliance rating plate.
5.  Replace regulator cover screw and tighten securely.
6.  Turn off all electrical power to the system.
7.   Remove manometer hose from outlet pressure hose barb.
8.  Remove hose barb and replace plug. Use pipe sealant.
9.  Plug in power cord.
10. Using a leak detection solution, check for leaks at pres-
sure boss screw.  Bubbles forming indicate a leak. SHUT 
OFF GAS AND FIX ALL LEAKS IMMEDIATELY.
ADJUSTMENT (cont.) 
LIGHTING INSTRUCTIONS